STANDARD STAND ALONE FILTER (SAF ) 5000-200

Recommended Filter Replacement is as follows:-

    Normal Working
1-2 Wave Single Shift
No Clean/Low Solids Fluxes
High Rosin Fluxes,
Lead Free Solders
or
Multi Shift Working
COMBI Filter
500-200-Combi
Cleaned Weekly Replace at Week 12
or on inspection
Replace at Week 8
or on inspection
Carbon Gas Filter
5000-200-4
Cleaned Weekly Replace between 9-15 Months
or on inspection
Replace between 8-14 Months
or on inspection

IMPORTANT NOTICE

PLEASE REPLACE THE FILTERS WITHIN THESE SCHEDULES AS INCORRECTLY MAINTAINED FILTERS WILL BLOCK THE AIR FLOW TO THE FAN. USING NON STANDARD FILTERS CAN CAUSE AIR FLOW PROBLEMS AND INVALIDATE THE WARRANTY.

 These figures are advisory and will vary with adherence to cleaning and service schedules and on fluxes and processes in use at each location. No Clean Fluxes and Low Solids may extend the schedule above.

Weekly Maintenance Schedule

 EACH WEEK please VACUUM each filter in the filter stack. This will greatly enhance the effectiveness and longevity of the filters and pay dividends in the long run.

ALL FILTERS MUST BE FITTED IN ACCORDANCE WITH DIRECTION ARROWS.

PLEASE REPLACE IN CORRECT ORDER

WARNING : When the filter is removed from the machine please remember to wear gloves and mask. Then it should be SEALED in a plastic bag and disposed of safely. Thank you.

Fuse Replacement

The Stand Alone Filter has its own 2 amp fuse for electrical protection. This is housed in a small push out fuse holder located just above the on off switch.

Configuration of Filters – Standard SAF

This unit has three Air inlets, one for the main body of the machine which connects from the top extraction to the inlet below the handle; the other two are blanked for potential use with high solids fluxes.

The filters used in the standalone filtration unit are as follows:

a) Combination Filter
Part No 5000-200-Combi

250 x 250 x 105mm
Specially constructed HIGH FLOW COMBINATION PANEL FILTER
with electrostatic properties.
Enhanced solids capture capacity and longer life.
d) Carbon Gas Filter
Part No: 5000-200-4

250 x 250 x 116mm

Impregnated deep bed split into 9 equal cells. Specially constructed moulded polypropylene with bonded material membrane.
Weight approximately 5.0 Kgs – 12.0 lbs .

NEW CONFIGURATION – COMBINATION FILTER 5000-200-COMBI

Filters out fumes, smoke and particles to less than 0.6 micron. Negative internal air pressure and simultaneous hopper extraction prevents escape of smoke, dust and fumes during loading and operation.

STAND ALONE FILTRATION (SAF) SYSTEM
with
EVS 5000-200-COMBINATION FILTER

Advantages

  • Considerably enhanced dust holding ability of the stand alone filter whilst reducing resistance to air flow resulting in significant extension of the as new air flow capability.
  • Significant increase in the life of the combi filter up to ten times the life expectancy of the previous first and second filter.
  • Reduced handling and cleaning of filters by the extended longevity of the new combination filter.
  • Reduced parts stock holding (2 filters not 4 filters) and filter waste handling.

Conclusion

The combination filter, increased air flow and dust/smoke capture improves all aspects of the EVS working practices and enhances your environmental credentials.

With its unique simplicity of operation and high recovery rates the EVS 5000-200-Combi gives fast payback, and enhances your company’s ability within ISO 14001 the corporate environmental standard.

EVS 5000-2000 STAND ALONE FILTER (SAF)

a) Total System Weight 30 Kgs – 67.5 lbs
b) Dimensions 32cm x 32cm x 56cm

 

 

web: www.solderrecovery.com